造成山特UPS电源自动关机的故障一般有三点一是静态开关二是电压不足三就是蓄电池损坏
山特ups电源出现故障自动关机这种情况的首选要排除的问题,是用于将负载从逆变器切换到旁路的静态开关是否出现问题。这个是最重要的,也是最容易被忽略的故障点之一。
有很多人不懂什么叫静态开关,静态开关其实就是静态转换的开关主要作用是一旦山特UPS电源发生故障、负载过载或使电池放电结束时,使负载能无间断的自动转到静态旁路,由旁路电源(市电)供电;提高系统的可靠性,同时也能提高山特UPS电源的过载能力。
电池的电压不足或者蓄电池的损坏,也是导致山特UPS电源自动关机的主要故障点之一。所以要养成经常检测以及保养UPS蓄电池的良好习惯。
详细参数
|
LC-P系列---后备浮充使用长寿命品 |
||||||||||
|
型 号 |
电压(V) |
容量(Ah) |
外型尺寸(mm) |
端子型号 |
单重 |
|||||
|
长(L) |
宽(W) |
高(H) |
总高(TH) |
|||||||
|
6 |
1.3 |
97 |
24 |
50 |
55 |
187 |
0.25 |
|||
|
6 |
7.2 |
151 |
34 |
94 |
100 |
187& 250 |
1.30 |
|||
|
6 |
12 |
151 |
50 |
94 |
100 |
187& 250M |
2.00 |
|||
|
6 |
200 |
407 |
173 |
210 |
250 |
M10 T |
33.5 |
|||
|
12 |
1.3 |
97 |
47.5 |
50 |
55 |
187 |
0.55 |
|||
|
12 |
2.2 |
177 |
34 |
60 |
66 |
187 |
0.80 |
|||
|
12 |
3.4 |
134 |
67 |
60 |
66 |
187 |
1.20 |
|||
|
12 |
7.2 |
151 |
64.5 |
94 |
100 |
187& 250M |
2.50 |
|||
|
12 |
12 |
151 |
98 |
94 |
100 |
187& 250M |
3.65 |
|||
|
12 |
16 |
151 |
98 |
99 |
105 |
187& 250M |
4.10 |
|||
|
12 |
17 |
181 |
76 |
167 |
167 |
M5 L& M5 A |
5.45 |
|||
|
12 |
20 |
181 |
76 |
167 |
167 |
M5 L& M5 A |
5.80 |
|||
|
12 |
24 |
165 |
125 |
175 |
179.5/175 |
M5 L& M5 A |
8.05 |
|||
|
12 |
28 |
165 |
125 |
175 |
179.5/175 |
M5 L& M5 A |
9.40 |
|||
|
12 |
38 |
197 |
165 |
175 |
180/175 |
M6 L& M5 A |
12.5 |
|||
|
12 |
42 |
197 |
165 |
175 |
180/175 |
M6 L& M5 A |
13.5 |
|||
|
12 |
65 |
350 |
166 |
175 |
175 |
M6 L |
19.0 |
|||
|
12 |
75 |
350 |
166 |
175 |
175 |
M6 L |
21.5 |
|||
|
12 |
100 |
407 |
173 |
210 |
236 |
M8 L |
29.0 |
|||
|
12 |
100 |
407 |
173 |
210 |
236 |
M8 L |
36.5 |
|||
|
12 |
120 |
407 |
173 |
210 |
236 |
M8 L |
34.5 |
|||
|
12 |
150 |
532.4 |
183.3 |
209 |
235/214 |
M8嵌入式铜芯 |
45.0 |
|||
山特UPS电源资讯
Thank you for purchasing our product. Observe the warnings on the machine and manual strictly and properly keep the manual. Do not operate the UPS before read safety notes and operation instructions.
INDEX
1.1 Description of the Symbols
Chapter 2 Product introduction
3.3 Procedure of UPS cable connection
3.5 Connected to the computer interface
3.6 Installation of intelligence card
3.9.1 Dust-proof network(optional)
4.1.3 LED operation panel explanation
4.2.2 DC without utility power
4.4 LED panel light and display
4.5 LCD Panel light and display :
4.6 LCD panel lcd display content
6.1 LED Panel trouble shooting
6.2 LCD panel trouble shooting
Appendix A Rack mounted battery pack
Appendix B intelligent slot (Optional)
All of the symbols as listed in the table below maybe used in this manual .This symbols are used for reminding users of safety notes for installation, operation ,and maintain.
|
Symbol & Description |
|
|
Symbol |
Description |
|
|
Caution,danger |
|
|
Danger electric shock |
|
|
Alternating current(AC) |
|
|
Direct current(DC) |
|
|
Protective ground |
|
|
Recycle |
|
|
Do not dispose with ordinary trash |
1.Read this manual carefully and thoroughly before operation the UPS and save this manual properly for reference.
2. When operating,please pay attention to all the alarming marks and operate in required.
3. Avoid direct sunlight, rain, or in a wet environment to use this equipment
4.This UPS can not be installed near the heat source area, or an electric heater, furnace and other similar equipment .
5.When placing UPS,leave a distance around to ensure ventilation. When installing,please refer to the instructions
6.Wipe with dry goods when cleaning.
7. In the event of fire occurring in the vicinity, please use dry powder fire extinguishers. The use of liquid fire extinguishing agents cause electric shock.
1.3 Electric safety
1. Before power, make sure is properly grounded, and check the wiring and the battery polarity is connected correctly
2. When the UPS need to move or re-wiring, disconnect the AC input power and to ensure that UPS is completely shut down, otherwise the output may still be charged, and there is the risk of electric shock
3. Please use our attachments and accessories specified.
4. To comply with EMC requirements, UPS's output line length should be within 10 meters
1.4 Battery safety
1. Battery life shorten with arising ambient temperature. Replace battery regularly can ensure it works and to ensure adequate back-up time.
2. Battery maintenance only be operated by professional personel who have barrtey knowledge.
3. There is risk of electric shock and short circuit the battery current danger. To avoid electric shock injury accident in the replacement battery, please observe the following warning:
A. Do not wear watches, rings or similar metal objects
B. Use insulated tools
C.Wear rubber boots and gloves
D. Do not put metal tools or similar metal parts on the battery
E. Before the separation of the battery connection terminals,you must first disconnect the load on the battery.
4.. Do not expose of batteriy to the fire, they may explode.and endanger safety
5. Non-professionals do not open or mutilate the battery, because batteries contains electrolyte acid and other hazardous substances, which will cause skin and eye damage. If you accidentally come into contact with the electrolyte, wash with plenty of water immediately and go to the hospital
6. Do not short the positive and negative of the battery electrode, otherwise, it may result in electric shock or fire.
1.5 Maintenance
1. Method of using the environment and save the life and reliability of this product have an impact,do not work in the following environments:
A. Exceed the specfications (temperature 0℃ ~ 40℃, relative humidity 20% ~ 90%) of the high and low temperatures and wet places
B. Vibration or shocks places
C. Metallic dust, corrosive substances, salt and flammable gases
2. If the extended period of time is not used, must be UPS (without batteries) stored in a dry environment, the storage temperature range: -25℃ ~ +55℃. UPS power, you must warm up the ambient temperature above 0℃ and keep 2 hours